FireCom Intelligent Fire Alarm Transmission System

Certified fire alarm and fault warning transmission equipment. Dual-path communication over GSM 4G/LTE and LAN.

See how an alarm travels through the system
Standby: the system monitors both paths
How the FireCom System works A detector reports a fire to the fire alarm control panel, which passes the zone alarm to the FireCom transmitter (alarm transmission equipment). FireCom sends it simultaneously over two physically separate paths, a wired path isolated from the Internet and a cellular path in a dedicated APN, to the retransmission station in the receiving centre of the fire monitoring system operator, Orange Polska. The retransmission station automatically acknowledges receipt to the transmitter and retransmits the alarm to the receiving station at the headquarters of the Polish State Fire Service, which receives it, additionally confirms receipt (the confirmation returns to the control panel at the premises on output PGM1) and creates an incident in the State Fire Service command support system (SWD-ST). The rescue team support module makes the premises data available to the fire crew. PROTECTED PREMISES Closed MPLS network Technology supported by Orange OPERATOR'S RECEIVING CENTRE · ORANGE LAN + GSM LAN + GSM headquarters LAN Wired path · isolated from the Internet GSM 4G/LTE path · dedicated APN no public Internet encryption · premises key Detector zone 3 · floor 2 Control panel indicates zone FIRE · ZONE 3 receipt confirmed FireCom alarm transmitter encoding… sends on 2 paths technical ACK ✓ PGM1 · received LAN ✕ · 4G ✓ Retransmission station decrypted ✓ Alarm retransmission to receiving station · LAN + GSM decryption technical ACK 2 paths → station Receiving station, fire HQ standby siren · beacon accepted SWD-ST fire dispatcher no incidents new incident confirmed Fault centre fault warnings paths OK path fault Fire crew support module at station Premises data card B H
  1. A detector senses fire, the panel indicates the zone

    The fire detector is part of the fire detection and alarm system and reports its activation to the fire alarm control panel. The panel determines in which detection zone the fire started and initiates alarm transmission.

  2. The panel passes the alarm to the FireCom transmitter

    The control panel passes the event to the FireCom alarm transmission equipment via a relay output to an I/O input, or over an RS485 bus using the ESPA 4.4.4 protocol, in which case the zone number is included too. The transmitter is certified to EN 54-21 (adopted in Poland as PN-EN 54-21) and works with control panels from various manufacturers.

  3. Two physically separate paths, transmitting simultaneously

    FireCom encodes the event as Contact ID codes, encrypts it with the per-premises encryption key and transmits it simultaneously and independently over two physically separate paths, wired and cellular GSM 4G/LTE, in line with the requirements of the regulation of the Polish Minister of the Interior and Administration. A failure of one path does not stop the alarm.

  4. Dedicated paths, isolated from the Internet

    The wired path is an isolated path in the operator's separate IP MPLS backbone network, with no connection of any kind to the Internet. The GSM 4G/LTE path is a dedicated path set up in the operator's public network, in a dedicated APN, with SIM cards assigned to the devices. Orange Polska, the fire monitoring system operator, holds a radio licence granted on an exclusive basis for the use of this path. Both paths are Type 1 links.

    Orange Technology supported by Orange

  5. The retransmission station acknowledges and retransmits the alarm

    Both paths terminate at the retransmission station in the receiving centre of the fire monitoring system operator, Orange Polska. The retransmission station is an intermediary device running in a high-availability cluster. It decrypts the frame with the premises key and, once the frame is stored, automatically sends the transmitter a technical acknowledgement (ACK); without it, FireCom would repeat the transmission. It then retransmits the alarm to the receiving station of the relevant headquarters of the Polish State Fire Service, in parallel over two paths: wired and GSM.

  6. The receiving station receives the alarm and confirms receipt

    The alarm is received by the alarm and fault receiving station at the State Fire Service headquarters: the siren and indicator lamp come on, and the message arrives in parallel over the wired and GSM paths. The station additionally confirms receipt of the alarm. The confirmation returns to the control panel at the premises as a signal on the transmitter's PGM1 output (an EN 54-21 requirement); if it is missing, output PGM2 signals this. The entire transmission from the fire detection system to the station takes under 10 s on average (class D4) and 20 s at most (M4). Discover the receiving station.

  7. Incident in SWD-ST and acceptance by the duty officer

    The incident in SWD-ST, the State Fire Service command support system, is created by the receiving station, on the local network of a headquarters integrated with SWD-ST. The State Fire Service duty officer accepts the alarm at the station within a set time limit (if the limit is exceeded, the operator is notified). The SWD-ST entry is confirmed.

  8. The crew sets off knowing the building

    The rescue team support module (WERG) opens the premises data card with the alarm context: access and fire access routes, appliance position, recommended entrance, water supply, fire protection installations, hazards and contacts. Reconnaissance begins while the crew is still en route.

  9. Path failure? The alarm still gets through

    If the wired link goes silent, alarms get through over the GSM 4G/LTE path. The loss of the path is detected and reported as a fault to the operator's fault receiving centre. State Fire Service screens are not burdened with technical events, and the loss of one path does not count as system unavailability (EN 50136-1-1, adopted in Poland as PN-EN 50136-1-1).

Transmission paths

Two paths, both dedicated and isolated from the Internet

FireCom transmits every alarm simultaneously over two physically separate paths. Both are dedicated paths, isolated from the Internet, and meet the requirements of the Polish Ministry of the Interior and Administration regulation for fire alarm transmission systems.

Path 1 · wired

Isolated wired path

A dedicated path in the operator's separate IP MPLS backbone network, implemented as a private VPN. It has no connection of any kind to the Internet.

  • Dedicated path in Orange Polska's separate IP MPLS network, which has no connection to the Internet, secured at the interface with the premises
  • No interface with the Internet whatsoever: alarm traffic is isolated from public traffic
  • Encryption with an individual key for each premises
  • Continuous path monitoring: loss of the path is detected and reported as a fault (class T5)
  • Type 1 link
Path 2 · cellular

Dedicated GSM 4G/LTE path

A dedicated path set up in the telecommunications operator's public network. Traffic runs in a dedicated APN, with no Internet access.

  • Dedicated APN, no Internet access; the path is physically separate from and independent of the wired path
  • SIM cards assigned to specific devices
  • The fire monitoring system operator, Orange Polska, holds a radio licence granted on an exclusive basis for the use of the path
  • Encryption with an individual key for each premises, continuous path monitoring (class T3)
  • Type 1 link, can serve as the primary link

Regulation of the Polish Minister of the Interior and Administration of 20 June 2007 on the list of products used to ensure public security or to protect health, life and property, and on the rules for issuing approvals for the use of these products (Journal of Laws 2007 No. 143, item 1002, as amended). Standards and compliance.

Critical infrastructure

Your own monitoring station is only half the security

Power plants, military units, fuel depots and data centres often have their own control room, in-house fire brigade and an extensive BMS. Yet few check how the alarm actually gets from the site to that station.

  • Do you know the link is working? Without continuous monitoring, a failure only comes to light during a fire.
  • Does the alarm travel over the Internet? A VPN tunnel over a public network is a target for attacks and shares its risk with the IT network.
  • Does the site know the alarm was received? Without receipt confirmation, the control panel at the site has no way of knowing.
Your monitoring centre no Internet path monitoring receipt confirmation 2 paths · via the operator's retransmission station

FireCom is a system, not a single device

A FireCom alarm transmission system consists of the transmitting device at the protected premises, a receiving station at the State Fire Service headquarters, and the receiving centre of the fire monitoring system operator, Orange Polska S.A. The solution is supplied by F&K Consulting Engineers, partner of Orange Polska S.A.

Alarm transmission equipment at the protected premises

Fire alarm and fault warning transmission equipment connected to the fire alarm control panel. It transmits events (Contact ID codes) simultaneously over two paths - wired IP and GSM 4G/LTE - using an encrypted alarm transmission protocol, with an individual key for each premises. On its PGM outputs it returns to the panel the confirmation that the State Fire Service station has received the alarm. This is the device described on this page.

Receiving station at the State Fire Service headquarters

An alarm and fault receiving station at the command post of the district or municipal State Fire Service headquarters, with a touchscreen display and visual and audible signalling. It is the station that formally receives the alarm and confirms its receipt, and at headquarters integrated with SWD-ST it creates the incident there itself. Designed in accordance with CLC/TS 50136-4. Discover the receiving station.

Operator's receiving centre

The retransmission station receives messages from both paths, decrypts them with the premises key and automatically sends a technical acknowledgement (ACK) back to the transmitter. It retransmits the alarm to the receiving station of the relevant State Fire Service headquarters in parallel over two paths - wired and GSM. It routes fault signals to the operator's fault receiving centre. It monitors path availability and manages the alarm queue in accordance with CLC/TS 50136-4.

The FireCom System runs entirely on the telecommunications operator's IP infrastructure - in a separate IP MPLS network and in a dedicated APN - without the public Internet. It uses neither the PSTN network, which is being phased out, nor its own VHF radio band. Why PSTN is no longer an option.

Why FireCom?

FireCom is alarm transmission equipment (UTA), also known in Polish industry terminology as UTAPiU: fire alarm and fault warning transmission equipment.

GSM 4G/LTE path - a dedicated path in the operator's network

The radio path is a dedicated transmission path set up in the operator's public network: a dedicated APN, SIM cards assigned to specific devices, no Internet access. The fire monitoring system operator, Orange Polska, holds a radio licence granted on an exclusive basis for the use of the path. The path qualifies as a Type 1 link. There is no need to build your own transmitters or maintain PSTN/ISDN lines.

Wired IP path - isolated from the Internet

Dedicated path in Orange Polska's separate IP MPLS network, which has no connection to the Internet, secured at the interface with the premises. Medium: FTTH fibre or Ethernet. Encryption with an individual key for each premises and continuous path monitoring - loss of the path is reported as a fault. Type 1 link.

Fire Alarms

The alarm reaches the State Fire Service receiving station in under 10 s on average (class D4) and within 20 s at most (class M4), counted from when the control panel passes on the signal. The station confirms receipt, and the confirmation returns to the control panel at the premises on output PGM1.

Fault Warnings

Fault signals from the fire protection system are routed automatically to the fault receiving centre of the fire monitoring system operator, Orange Polska. The centre passes them on to service companies. They do not burden the State Fire Service command post.

High Reliability

Two physically separate paths - wired and GSM - transmit every alarm simultaneously and independently. Both are Type 1 links, so either can be the primary one. Loss of a path is reported in class T5 for the wired path and T3 for the GSM path.

Fire Detection System Integration

Connection to the relay outputs (PGM) of a fire alarm control panel from any manufacturer, or over an RS485 bus using the ESPA 4.4.4 protocol. Outputs PGM1-PGM3 return receipt confirmation and connection status to the panel.

Intelligent Support

FireCom is more than alarm transmission

Above all, it provides comprehensive situational support for rescue teams. FireCom is not just fire alarm transmission equipment. The rescue team support module (WERG) of the FireCom System provides context-aware support to State Fire Service firefighting and rescue teams.

Direct Transmission

FireCom automatically sends the alarm over two paths, via the retransmission station in the receiving centre, to the receiving station at the State Fire Service headquarters. At headquarters integrated with SWD-ST, the receiving station creates a new incident there, eliminating delays in responding to the threat.

Rescue Team Support Module

Alongside alarm transmission, the FireCom System's rescue team support module gathers and provides key contextual information that supports the rescue operation.

Intelligent Navigation

The rescue team support module shows access routes and fire access routes, the appliance position and the recommended building entrance.

Operational reconnaissance before arriving on site

Every second counts during firefighting and rescue operations. The rescue team support module gives State Fire Service crews access to critical information while they are still en route to the incident, significantly shortening reconnaissance time and speeding up the start of the right actions.

Modern fire protection challenges call for modern solutions. As the most versatile rescue service, the fire service must be ready to operate in any conditions. The rescue team support module supports this goal, turning reconnaissance from a source of delay into an operational advantage.

  • Shorter building reconnaissance time
  • Faster access to the source of the hazard
  • Greater safety for rescue teams

Integration with the FireCom system means that the contextual information from the rescue team support module is available together with the alarm, giving rescue teams a full picture of the situation before they arrive at the scene. It is an ideal solution for public buildings, multi-family residential buildings, shopping centres, and industrial and warehouse facilities. Passing on hazard information as quickly as possible enables more effective rescue operations and reduces fire losses.

FireCom Specification

Key parameters of the device in the FireCom System.

Power supply
EN 54-4
with backup battery
Transmission channels
LAN + 4G
FTTH/Ethernet and 4G/LTE
Transmission paths
2
transmitted simultaneously
Transmission time
D4 · M4
under 10 s on average, max. 20 s
Operating temperature
-10…+50 °C
humidity up to 80% at +20 °C
Certificate
1922-CPR-2083
EN 54-21:2006, EN 54-4
Full technical specification

Paths and transmission

Transmission paths
2, transmitted simultaneously and independently: wired IP path (Ethernet/FTTH) in the operator's separate IP MPLS network and 4G/LTE path in a dedicated APN; neither has Internet access
Protocols
Encrypted transmission; Contact ID event codes
Encryption
Individual key for each premises between the premises and the receiving centre, TLS beyond that
SIM card
2 × nano-SIM in a single radio path (backup card, not a second path)

Connection to the control panel

Connection to the fire alarm control panel
Inputs for the relay outputs of control panels from any manufacturer, or RS485 bus (ESPA 4.4.4, with zone number)
Feedback signals to the control panel (EN 54-21 requirement)
PGM1 - receipt confirmation from the State Fire Service receiving station; PGM2 - no confirmation or loss of communication with the station; PGM3 - loss of communication with the receiving centre

Classification

FireCom System classification (EN 50136-1-1)
D4 (under 10 s on average), M4 (max. 20 s), T5 (wired path) / T3 (GSM path), A4, S2, I2

Power supply, environment, certificate

Power supply
EN 54-4 compliant power supply with backup battery
Operating temperature
From -10 °C to +50 °C (relative humidity up to 80% at +20 °C)
Certificate
1922-CPR-2083 (EN 54-21:2006, EN 54-4), declaration of performance (DoP) under the CPR

Full datasheet, power budget and installation manual for designers and installers on request.

Certificates and Standards

The FireCom device holds a certificate of conformity under the CPR system.